Output Assembly kits
To increase output power, outputs of multiple SM15K units can be connected in parallel or in series. Together with the plug-and-play M/S interface of the SM15K, multiple units will operate as one big system. In such a system, the SM15K units serve as a modular building block.
In order to quickly and safely assemble and reconfigure a system of multiple SM15K units, dedicated output assembly kits are offered. Different output kits are offered per SM15K unit type, as their current and voltage ranges differ.
At this moment, the SM15K units allow the operation of up to 60 units in parallel or several in series. We offer kits for a fixed number of units in parallel or in series. A complete and detailed overview can be found in the order codes of the SM15K unit. For a simplified overview of the available kits, see the options section below.
Each kit contains:
- Bus-bars for electrical connections
- Communication cables to interconnect the Master-Slave interface-modules of each power supply
- Safety covers or spacers for protection
- Nuts and bolts for mounting the bus-bars securely
Furthermore, our distributors offer custom cabinet systems, built to your individual needs.
Features
- Easy assembly and reconfiguration of multiple SM15K outputs
- Bus bars to connect the outputs of the power supply units
- Cables to connect the plug-and-play master/ slave interfaces
- Output safety covers
- Kits can be combined and stacked
Functionalities
- Building block for a modular high-power system of SM15K units
- Connecting outputs in parallel or series
- Master/Slave operation when using the plug-and-play master/ slave interfaces
Options
Product options
2x parallel SM70-CP-450
Choice of:
- M/S-PAR-SET A2, for two units in parallel.
- M/S PAR-SET-A2-2CBL. Special version of M/S-PAR-SET A2, with only two (thick) cables out instead of 4 thinner ones. This kit is shown in the pictures on this page.
3x parallel SM70-CP-450
M/S-PAR-SET A3, for three units in parallel.
4x parallel SM70-CP-450
M/S-PAR-SET A4, for four units in parallel.
5 - 60x parallel SM70-CP-450
- M/S-PAR-SET A5 — A6, for 5 to 6 units in parallel.
- 6 to 60 in parallel — contact factory for assistance
2x parallel SM210/500/1000/1500
M/S-PAR-SET C2, for two units in parallel.
3x parallel SM210/500/1000/1500
M/S-PAR-SET C3, for three units in parallel.
4x parallel SM210/500/1000/1500
M/S-PAR-SET C4, for four units in parallel.
5 - 60x parallel SM210/500/1000/1500
- M/S-PAR-SET C5 — C12, for 5 to 12 units in parallel
- 12 to 60 in parallel — contact factory for assistance
2x series SM500-CP-90
M/S-SER-SET-BA, base set for 2 units in series
3x series SM500-CP-90
Requires both:
- 1x M/S-SER-SET BA, base set for 2 units in series
- 1x M/S-SER-SET BB, extension set
4x series SM500-CP-90
Requires both:
- 1x M/S-SER-SET BA, base set for 2 units in series
- 2x M/S-SER-SET BB, extension sets
5 - 6x series SM500-CP-90
Requires both:
- 1x M/S-SER-SET BA, base set for 2 units in series
- 3 - 4x M/S-SER-SET BB, extension sets
Support items
Downloads
| Data sheets | Type/Format | Size |
|---|---|---|
| Data sheet Interfaces SM15K series | 521.36 KB |
| Manuals | Type/Format | Size |
|---|---|---|
| Manual Interfaces SM15K series | 1.49 MB |
| Application notes | Type/Format | Size |
|---|---|---|
| Application note Master/Slave parallel operation SM70-CP-450 | 8.71 MB | |
| Application note Master/Slave parallel operation SM210-CP-150 | 20.72 MB | |
| Application note Master/Slave series operation SM500-CP-90 | 2.39 MB | |
| Application note Master/Slave parallel operation SM500-CP-90, SM1000-CP-45 and SM1500-CP-30 | 21.39 MB |